Search results for "electronic devices"

showing 10 items of 46 documents

Growth kinetics of colloidal Ge nanocrystals for light harvesters

2016

Colloidal Ge nanocrystals (NCs) are gaining increased interest because of their potential application in low-cost optoelectronic and light harvesting devices. However, reliable control of colloidal NC synthesis is often an issue and a deeper understanding of the key-role parameters governing NC growth is highly required. Here we report an extended investigation on the growth of colloidal Ge NCs synthesized from a one-pot solution based approach. A systematic study of the effects of synthesis time, temperature and precursor concentration is elucidated in detail. X-ray diffraction (XRD) analysis reveals the presence of crystalline Ge NCs with a mean size (from 5 to 35 nm) decreasing with the …

Materials scienceScanning electron microscopePHOTODETECTORSGeneral Chemical EngineeringPhotodetectorNanotechnology02 engineering and technologyActivation energy010402 general chemistry01 natural sciencesSettore ING-INF/01 - ElettronicaColloidDynamic light scatteringPEDOT:PSSGermanium; Quantum dot; PHOTODETECTORSchemistry.chemical_classificationGermaniumQuantum dotGeneral ChemistryPolymer021001 nanoscience & nanotechnology0104 chemical scienceschemistryChemical engineeringNanocrystaloptoelectronic devices colloidal nanocrystals0210 nano-technology
researchProduct

Metabolic Status and Reaction to Heat of Normal and Tumor Tissue

1995

The occurrence of differential heating and differential thermal sensitivity between malignant tumors and normal tissues is thought to be due to limited heat dissipation and energy depletion in many solid tumors which in turn results from an inadequately functioning tumor microcirculation (Jain and Ward-Hartley 1984; Song 1984, 1991; Vaupel and Kallinowski 1987; Reinhold 1988; Vaupel et al. 1988a; Vaupel 1990). As a consequence of the latter pathophysiological condition, supply and drainage function are restricted in many solid tumors or, at least, in some tumor areas, thus creating a hostile metabolic microenvironment characterized by tissue hypoxia, acidosis, and energy depletion. Thermal …

ChemistrymedicineCancer researchNormal tissueTissue hypoxiaFunctioning tumorThermal management of electronic devices and systemsmedicine.symptomTumor tissuePerfusionAcidosisMicrocirculation
researchProduct

Adherence to growth hormone (GH) therapy in naïve to treatment GH-deficient children: data of the Italian Cohort from the Easypod Connect Observation…

2019

Background: With the use of non-objective measurement, adherence to growth hormone (GH) therapy has been reported suboptimal in a large proportion of patients, and poor adherence has been shown to affect short-term growth response in patients receiving GH treatment. Objective: The Easypod™ electronic device allows objective measurement of adherence. In this study, we report 3-year prospective adherence data of the Italian cohort of naïve GH deficient (GHD) children extrapolated from the Easypod Connect Observational Study (ECOS) database. Patients and methods: Seventy-three GHD children naïve to GH treatment were included in the analysis. 22 Italian centers participated in the study. Result…

MalePediatricsDatabases FactualChildren; ECOS; GHD; Growth hormone; Short statureEndocrinology Diabetes and MetabolismChildren; ECOS; GHD; Growth hormone; Short stature;Children; ECOS; GHD; Growth hormone; Short stature; Adolescent; Child; Cohort Studies; Databases Factual; Dwarfism Pituitary; Female; Growth Disorders; Human Growth Hormone; Humans; Italy; Male; Medication Adherence; Telemedicine; Medical Records Systems Computerized; Wearable Electronic DevicesGrowth hormoneCohort Studies0302 clinical medicineEndocrinologyChildChildrenGrowth DisordersHuman Growth HormoneChildren ECOS GHD Growth hormone Short statureObjective measurementSettore MED/38TelemedicineItaly030220 oncology & carcinogenesisCohortFemaleOriginal ArticleMedical Records Systemsmedicine.symptomCohort studymedicine.medical_specialtyAdolescentMedical Records Systems ComputerizedDwarfism030209 endocrinology & metabolismShort statureMedication AdherenceDatabasesWearable Electronic Devices03 medical and health sciencesmedicineHumansIn patientDwarfism PituitaryGrowth hormoneFactualbusiness.industryComputerizedShort staturePituitaryGh treatmentECOSObservational studybusinessGHDJournal of Endocrinological Investigation
researchProduct

Gait Variability Using Waist- and Ankle-Worn Inertial Measurement Units in Healthy Older Adults

2020

Gait variability observed in step duration is predictive of impending adverse health outcomes among apparently healthy older adults and could potentially be evaluated using wearable sensors (inertial measurement units, IMU). The purpose of the present study was to establish the reliability and concurrent validity of gait variability and complexity evaluated with a waist and an ankle-worn IMU. Seventeen women (age 74.8 (SD 44) years) and 10 men (73.7 (4.1) years) attended two laboratory measurement sessions a week apart. Their stride duration variability was concurrently evaluated based on a continuous 3 min walk using a force plate and a waist- and an ankle-worn IMU. Their gait complexity (…

MaleReproducibility of Resultsdynamicslcsh:Chemical technologygaitArticlewearablekävelyWearable Electronic DevicesaccelerometerHumansnon-linearFemalelcsh:TP1-1185liikeanalyysibiomekaniikkaAnkleGait Analysishuman activitiesikääntyneetAged
researchProduct

Portable PSG for sleep stage monitoring in sports: Assessment of SOMNOwatch plus EEG.

2019

Current sport-scientific studies mostly neglect the assessment of sleep architecture, although the distribution of different sleep stages is considered an essential component influencing an athlete's recovery and performance capabilities. A mobile, self-applied tool like the SOMNOwatch plus EEG might serve as an economical and time-friendly alternative to activity-based devices. However, self-application of SOMNOwatch plus EEG has not been validated against conventional polysomnography (PSG) yet. For evaluation purposes, 25 participants (15 female, 10 male;

AdultMalemedicine.medical_specialtyTime Factorsmedia_common.quotation_subjectPolysomnographySleep REM030209 endocrinology & metabolismPhysical Therapy Sports Therapy and RehabilitationPolysomnographyElectroencephalographyNeglect03 medical and health sciencesWearable Electronic DevicesYoung Adult0302 clinical medicinePhysical medicine and rehabilitationConfidence IntervalsMedicineHumansOrthopedics and Sports MedicineElectrodesmedia_commonSleep Stagesmedicine.diagnostic_testbusiness.industryElectroencephalography030229 sport sciencesGeneral MedicineSleep LatencySleep architectureAthletesFemaleSleep (system call)Sleep StagesbusinessEuropean journal of sport science
researchProduct

Individual arc-discharge synthesized multiwalled carbon nanotubes probed with multiple measurement techniques

2020

Arc-discharge synthesized multiwalled carbon nanotubes (AD-MWNT), or related MWNTs, exhibit a good quality compared to the more common type of MWNT synthesized by catalytic chemical vapor deposition methods. Yet experimental measurements on these are rather few and typically have not correlated data from different measurement techniques. Here, the authors report Raman spectroscopy, scanning probe microscopy, conductivity measurements, and force microscopy on single AD-MWNTs. The results demonstrate the high quality of AD-MWNTs and are compatible with the view of them as the best approximation of MWNTs as an assembly of defect-free concentric individual single-walled carbon nanotubes. The au…

Materials sciencescanning probe microscopyCarbon nanotubeConductivitylaw.inventionnanotubesElectric arcsymbols.namesakeScanning probe microscopyraman spectroscopyatomifysiikkalawelectric dischargesMicroscopyMaterials ChemistryElectrical and Electronic EngineeringatomivoimamikroskopiaInstrumentationatomic force microscopyPhysicsProcess Chemistry and TechnologyConductanceSurfaces Coatings and FilmsElectronic Optical and Magnetic MaterialsChemical engineeringelectronic devicessymbolsscanning tunneling microscopynanoputketRaman spectroscopyEngineering sciences. TechnologyLayer (electronics)scanning electron microscopy
researchProduct

Validation of a novel contact-free heart and respiratory rate monitor.

2021

There is a growing need for remote monitoring of patients due to a lack of resources and infection control. Current systems use sensors that require constant physical contact with the user, which may result in discomfort or lack of adherence. In the present study, we evaluated the accuracy of a new contact-free system to monitor heart and respiratory rate. Study participants were measured simultaneously using two devices: a contact-free optical system that measures nano-vibrations and movements (investigational device, "Gili Pro BioSensor") and a standard reference bed-side monitor, inclusive of an electrocardiogram and capnograph modules (Mindray

Malemedicine.medical_specialtyRespiratory rate0206 medical engineeringBiomedical EngineeringVital signs02 engineering and technology01 natural sciencesWearable Electronic DevicesRespiratory RateHeart RateInternal medicineHeart rateMedicineHumansAgedMonitoring PhysiologicAged 80 and overContact freebusiness.industry010401 analytical chemistryArrhythmias CardiacGeneral MedicineMiddle Aged020601 biomedical engineering0104 chemical sciencesCardiologyFemaleCurrent (fluid)businessConstant (mathematics)Journal of medical engineeringtechnology
researchProduct

Field-driven domain wall motion under a bias current in the creep andflow regimes in Pt/[CoSiB/Pt](N) nanowires

2016

AbstractThe dynamics of magnetic domain wall (DW) in perpendicular magnetic anisotropy Pt/[CoSiB/Pt]N nanowires was studied by measuring the DW velocity under a magnetic field (H) and an electric current (J) in two extreme regimes of DW creep and flow. Two important findings are addressed. One is that the field-driven DW velocity increases with increasing N in the flow regime, whereas the trend is inverted in the creep regime. The other is that the sign of spin current-induced effective field is gradually reversed with increasing N in both DW creep and flow regimes. To reveal the underlying mechanism of new findings, we performed further experiment and micromagnetic simulation, from which w…

MultidisciplinaryMaterials scienceMagnetic domainCondensed matter physicsSpintronicsMagnetic devices02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesArticleAmorphous solidMagnetic fieldDomain wall (magnetism)Creep0103 physical sciencesElectronic devicesElectric current010306 general physics0210 nano-technologyAnisotropySimulation
researchProduct

Smart composite films of nanometric thickness based on copper-iodine coordination polymers. Toward sensors.

2018

One-pot reactions between CuI and methyl or methyl 2-amino-isonicotinate give rise to the formation of two coordination polymers (CPs) based on double zig-zag Cu2I2 chains. The presence of a NH2 group in the isonicotinate ligand produces different supramolecular interactions affecting the Cu-Cu distances and symmetry of the Cu2I2 chains. These structural variations significantly modulate their physical properties. Thus, both CPs are semiconductors and also show reversible thermo/mechanoluminescence. X-ray diffraction studies carried out under different temperature and pressure conditions in combination with theoretical calculations have been used to rationalize the multi-stimuli-responsive …

Materials scienceFabricationPolymersThin filmsComposite numberSupramolecular chemistryNanocomposite films02 engineering and technologyOptoelectronic devices010402 general chemistry01 natural sciencesNanomaterialschemistry.chemical_classificationFilm thicknessChainsNanostructured materialsQuímicaGeneral ChemistryPolymerBinary alloys021001 nanoscience & nanotechnology0104 chemical sciencesChemistrychemistryChemical engineeringNanofiberNanometreFilm preparationSupramolecular chemistry0210 nano-technologyCoordination reactionsNanofibresCopperMechanoluminescenceIodineChemical science
researchProduct

Lead-Related Infective Endocarditis in Latvia: A Single Centre Experience

2019

Background and Objectives: Over the last five decades cardiac implantable electronic devices (CIED) have become established as the mainstay for the treatment of permanent bradycardias, chronic heart failure and dangerous heart rhythm disturbances. These devices improve survival and quality of life in many patients. However, infections associated with CIED implantation, particularly lead-related infective endocarditis (LRIE), can offset all benefits and make more harm than good for the patient. To date, there are no other studies in Latvia, addressing patients with lead-related infective endocarditis. The objective of this study was to identify the most common pathogens associated with LRIE …

AdultMalemedicine.medical_specialtymedicine.drug_classAntibioticsDiseasemedicine.disease_causeArticleAntibiotic resistanceQuality of lifelead-related infective endocarditisRisk FactorsInternal medicinemedicineHumansAgedRetrospective StudiesAged 80 and overHeart Failurelcsh:R5-920cardiac implantable electronic devicesEndocarditisbusiness.industryArrhythmias CardiacGeneral Medicinecardiac device infectionProstheses and ImplantsMiddle Agedmedicine.diseaseLatviaLRIE mortalityLeadStaphylococcus aureusEchocardiographyInfective endocarditisHeart failureCIED complicationFemalelead-related infective endocarditis; cardiac implantable electronic devices; cardiac device infection; CIED complication; LRIE mortalityCoagulasebusinesslcsh:Medicine (General)Medicina
researchProduct